Lecore Series EPV Emergency Pressure Vents are designed to provide emergency relief capacity beyond that furnished by the operating vent on the tanks. The Series EPV vents do not provide vacuum relief. Vacuum relief must be supplied by independent operating vents. Under normal operating conditions, the vent pallet assembly is closed providing an effective vapor seal. In the event of an emergency (fi re involvement of the tank), the pallet lifts in response to the increased pressure in the tank’s vapor space. Vapor is expelled, thereby protecting the tank from dangerous over-pressurization. Pallet assembly automatically closes and reseals when the pressure is reduced.

  • Vents directly to atmosphere
  • Sizes 2″ (50.8mm) through 24″ (609.6mm)
  • Settings achieved by weight loading
  • Minimum / maximum settings
  • Higher pressure settings available
  • Low-leak pallet design – certifi ed test reports
  • Design & light weight permit easy handling
  • Factory tested and certified

MATERIALS OF CONSTRUCTION:

Body : Carbon steel standard
Aluminium
Stainless steel
Seat : Carbon steel or Aluminium or stainless steel
Pallet : Aluminium or stainless steel
Screen : Stainless Steel AISI 304
Guides : Stainless Steel AISI 304
Diaphragm: Fluorinated Ethylene Propylene (FEP) / TFE
DCM Emergency Pressure Vents